Motor Connecting Cables
2YSLCY-JB/2YSLCYK-JB 9YSLCY-JB PENDANT CABLE  

Mineral insulated cables

MI Cable

Application

Public buildings

High-temperature sistuations

Hazardous location

Underground buildings

Transportation and Traffic juction

STANDARDS

BS 6387

BS EN 60702

BS 6207

Voltage Rating

500V, 750V

CABLE CONSTRUCTION

Conductors: Solid plain copper conductors.

Insulation: Magnesium Oxide (MgO).

Outer sheath: Plain copper sheath with optional LSZH covering.

Corrosion protective covering: LSF corrosion fire resistant outer sheath. (optional)

Electrical Characteristics at 20℃

Light Duty 0.5KV Grade

 

Nominal Conductor Diameter

 

mm

 

1.13

 

1.39

 

1.77

 

2.25

 

Nominal Conductor Cross Section

 

mm²

 

1.0

 

1.5

 

2.5

 

4.0

 

Maximum DC Conductor Resistance

 

Ω/km

 

18.1

 

12.1

 

7.41

 

4.61

 

Voltage Rating

 

KV

 

0.5

Heavy Duty 0.75KV Grade

 

Nominal Conductor Diameter

 

mm

 

1.39

 

1.77

 

2.25

 

2.75

 

3.57

 

4.50

 

5.66

 

6.66

 

7.75

 

Nominal Conductor Cross Section

 

mm²

 

1.50

 

2.5

 

4.0

 

6.0

 

10.0

 

16.0

 

25.0

 

35.0

 

50.0

 

Maximum DC Conductor Resistance

 

Ω/km

 

12.1

 

7.41

 

4.61

 

3.08

 

1.83

 

1.15

 

0.727

 

0.524

 

0.387

 

Voltage Rating

 

KV

 

0.75

 

 

 

Nominal Conductor Diameter

 

mm

 

9.32

 

10.98

 

12.33

 

13.7

 

15.18

 

17.33

 

19.37

 

22.37

 

Nominal Conductor Cross Section

 

mm²

 

70.0

 

95.0

 

120.0

 

150.0

 

185.0

 

240.0

 

300

 

400

 

Maximum DC Conductor Resistance

 

Ω/km

 

0.268

 

0.193

 

0.153

 

0.124

 

0.101

 

0.0775

 

0.0601

 

0.047

 

Voltage Rating

 

KV

 

0.75

Mechanical and Thermal Properties

Minimum Bending Radius: 2×OD (D<7);

3×OD (7 ≤ D<12); 4×OD (12 ≤ D<15); 6×OD (D ≥ 15)

Temperature Range: -80℃ to +105℃

Cable Parameter

Light Duty 0.5KV Grade

 

 

Cable Code

No. of cores
& Nominal Conductor Cross Sectional Area No.×mm²

 

Cross Sectional Area of Copper Sheath mm²

Nominal Overall Diameter
mm

 

Nominal Weight
kg/km

 

With LSZH
Covering

 

Without LSZH
Covering

 

With LSZH
Covering

 

Without LSZH
Covering

L-MICC-300/500V-2G1

2×1.0

5.4

6.4

5.1

126

104

L-MICC-300/500V-2G1.5

2×1.5

6.3

7.0

5.7

154

136

L-MICC-300/500V-2G2.5

2×2.5

8.2

7.9

6.6

206

187

L-MICC-300/500V-2G4

2×4.0

10.7

9.2

7.7

322

248

L-MICC-300/500V-3G1

3×1.0

6.7

7.1

5.8

159

136

 

 

 

Cable Code

No. of cores
& Nominal Conductor Cross Sectional Area No.×mm²

 

Cross Sectional Area of Copper Sheath mm²

Nominal Overall Diameter
mm

 

Nominal Weight
kg/km

 

With LSZH
Covering

 

Without LSZH
Covering

 

With LSZH
Covering

 

Without LSZH
Covering

L-MICC-300/500V-3G1.5

3×1.5

7.8

7.7

6.4

194

176

L-MICC-300/500V-3G2.5

3×2.5

9.5

8.8

7.3

272

223

L-MICC-300/500V-4G1

4×1.0

7.7

7.6

6.3

187

162

L-MICC-300/500V-4G1.5

4×1.5

9.1

8.3

7.0

231

203

L-MICC-300/500V-4G2.5

4×2.5

11.3

9.6

8.1

336

277

L-MICC-300/500V-7G1

7×1.0

11.0

9.3

7.6

269

236

L-MICC-300/500V-7G1.5

7×1.5

11.8

9.9

8.4

351

295

L-MICC-300/500V-7G2.5

7×2.5

15.4

11.2

9.7

475

411

Heavy Duty 0.75KV Grade

 

 

 

Cable Code

No. of cores
& Nominal Conductor
Cross Sectional Area No×mm²

 

Cross Sectional Area of Copper Sheath mm²

Nominal Overall Diameter
mm

 

Nominal Weight
kg/km

 

With LSZH
Covering

 

Without LSZH
Covering

 

With LSZH
Covering

 

Without LSZH
Covering

H-MICC-450/750V-1G6

1×6.0

8.0

7.7

6.2

213

173

H-MICC-450/750V-1G10

1×10.0

9.0

8.8

7.3

273

240

H-MICC-450/750V-1G16

1×16.0

12.0

9.8

8.3

361

326

H-MICC-450/750V-1G25

1×25.0

15.0

11.1

9.6

506

457

H-MICC-450/750V-1G35

1×35.0

18.0

12.2

10.7

650

585

H-MICC-450/750V-1G50

1×50.0

22.0

13.6

12.1

842

758

H-MICC-450/750V-1G70

1×70.0

27.0

15.2

13.7

1147

1016

H-MICC-450/750V-1G95

1×95.0

32.0

17.4

15.4

1520

1324

H-MICC-450/750V-1G120

1×120.0

37.0

18.8

16.8

1870

1612

H-MICC-450/750V-1G150

1×150.0

44.0

20.4

18.4

2230

1949

H-MICC-450/750V-1G185

1×185.0

54.0

23.2

20.4

2575

2370

H-MICC-450/750V-1G240

1×240.0

70.0

26.1

23.3

3312

3050

H-MICC-450/750V-1G300

1×300.0

79.0

28.8

26.0

3972

3791

H-MICC-450/750V-1G400

1×400.0

91.0

32.8

30.0

5211

5004

H-MICC-450/750V-2G1.5

2×1.5

11.0

9.4

7.9

259

237

H-MICC-450/750V-2G2.5

2×2.5

13.0

10.2

8.7

314

276

H-MICC-450/750V-2G4

2×4.0

16.0

11.3

9.8

398

355

 

 

 

 

Cable Code

No. of cores
& Nominal Conductor
Cross Sectional Area No×mm²

 

Cross Sectional Area of Copper Sheath mm²

Nominal Overall Diameter
mm

 

Nominal Weight
kg/km

 

With LSZH
Covering

 

Without LSZH
Covering

 

With LSZH
Covering

 

Without LSZH
Covering

H-MICC-450/750V-2G6

2×6.0

18.0

12.4

10.9

483

446

H-MICC-450/750V-2G10

2×10.0

24.0

14.2

12.7

697

619

H-MICC-450/750V-2G16

2×16.0

30.0

16.2

14.7

968

850

H-MICC-450/750V-2G25

2×25.0

38.0

19.1

17.1

1275

1178

H-MICC-450/750V-3G1.5

3×1.5

12.0

9.8

8.3

290

254

H-MICC-450/750V-3G2.5

3×2.5

14.0

10.8

9.3

365

323

H-MICC-450/750V-3G4

3×4

17.0

11.9

10.4

461

415

H-MICC-450/750V-3G6

3×6

20.0

13.0

11.5

590

526

H-MICC-450/750V-3G10

3×10

27.0

15.1

13.6

853

754

H-MICC-450/750V-3G16

3×16

34.0

17.1

15.6

1080

1034

H-MICC-450/750V-3G25

3×25

42.0

20.2

18.2

1548

1444

H-MICC-450/750V-4G1.5

4×1.54

14.0

10.6

9.1

344

305

H-MICC-450/750V-4G2.5

4×2.5

16.0

11.6

10.1

430

384

H-MICC-450/750V-4G4

4×4

20.0

12.9

11.4

577

507

H-MICC-450/750V-4G6

4×6

24.0

14.2

12.7

718

644

H-MICC-450/750V-4G10

4×14×160

30.0

16.3

14.8

1050

911

H-MICC-450/750V-4G16

4×16

39.0

19.3

17.3

1390

1286

H-MICC-450/750V-4G25

4×25

49.0

22.3

20.1

1943

1805

H-MICC-450/750V-7G1.5

7×1.5

18.0

12.3

10.8

478

432

H-MICC-450/750V-7G2.5

7×2.5

22.0

13.6

12.1

614

559

H-MICC-450/750V-12G1.5

12×1.555

28.0

15.8

14.1

772

712

H-MICC-450/750V-12G2.5

12×2.5

34.0

17.9

15.6

970

911

H-MICC-450/750V-19G1.5

19×1.5

37.0

18.9

16.6

1086

992